OEMASMLKarl Suss
CategoryLithographyLithography
Wafer size100mm100mm
Process node248 nm (KrF) DUV—
Introduced——
Production run1991–—
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyASML 5500Karl Suss MA-4
Cited variants
  • PAS 5500/300[1]
  • PAS 5500/200i-line[2]
  • PAS 5500/60i-line[3]
  • PAS 5500/275i-line[4]
—
Specifications
ManufacturerASML[1]—
ModelPAS 5500/300[1]MA-4[5]
DescriptionDeep-UV Stepper Photolithography[1]—
Exposure wavelength248 nm (KrF)[1]—
Configured wafer size4 in wafers[1]—
Maximum wafer size4 in (100 mm) wafers with SEMI standard wafer flat (not notch)[1]—
Layer-to-layer overlay accuracybetter than 30 nm[1]—
Minimum feature size≤150 nm isolated lines; ≤200 nm dense patterns[1]—
Full-field useable exposure areaintersection of a 31 mm diameter circle and a 22 mm x 27 mm rectangle[1]—
Sample size100 mm wafers with SEMI std. major flat[1]—
Alignment accuracy< 50 nm[1]—
Wafer thicknessminimum approximately 200 µm; maximum approximately 1.1 mm[1]—
Maximum dose~100 mJ[1]—
Minimum Feature Size (dense)≤200 nm[1]—
Minimum Feature Size (isolated lines)≤150 nm[1]—
Overlay AccuracyBetter than 30 nm[1]—
Maximum Field Size (usable exposure area)22 mm x 27 mm rectangle within a 31 mm diameter circle[1]—
Wafer Size (standard)4 inch (100 mm)[1]—
ThroughputTypically minutes per wafer (multiple 4-inch wafers)[1]—
Reduction Ratio5x (for some variants, e.g., /200 and /60)[2]—
Numerical Aperture (variable)0.48-0.60 (for /200 variant)[2]—
Alignment Accuracy< 50 nm (for /300 variant)[1]—
Resolution (PAS 5500/300)≤150 nm isolated lines, ≤200 nm dense patterns[1]—
Exposure wavelength (PAS 5500/60)365 nm[3]—
Reduction ratio (PAS 5500/60)5:1[3]—
Wafer size (PAS 5500/300)100 mm (4 inch) wafers with SEMI standard flat[1]—
Overlay accuracy (PAS 5500/300)better than 30 nm[1]—
Resolution (PAS 5500/200)350 nm[2]—
Numerical aperture (PAS 5500/200)0.48-0.60 variable[2]—
Maximum field size (PAS 5500/200)22x22 mm[2]—
Minimum feature size (PAS 5500/60)450 nm[3]—
OEM—Karl Suss[5]
Equipment type—Mask Aligner[5]
Substrate size—Up to 4" (100mm) in diameter[5]
Sample compatibility—Works for smaller samples[5]
Alignment mode—Contact/proximity aligner[5]
Illumination wavelengths—365 nm or 405 nm[5]
Backside alignment—Real-time infrared through-wafer backside alignment[5]

Plan your fab

Building a Lithography process? Get a complete equipment list.

Open the fab equipment planner →
Sources (5)Every fact above is drawn from these public sources
  1. [1]wiki.nanotech.ucsb.eduwiki.nanotech.ucsb.edu
  2. [2]manualslib.commanualslib.com
  3. [3]snfguide.stanford.edusnfguide.stanford.edu
  4. [4]asml.comasml.com
  5. [5]nanocenter.umd.edunanocenter.umd.edu