Waferpedia

Comparison ledger

Rainbow 4520versusPlasmalab 80 Plus RIE

Lam Research Rainbow 4520, Oxford Instruments Plasmalab 80 Plus RIE, side by side. Every value shown is drawn from the cited encyclopedia entries.

Documented as functional equivalents— Same function class: Etch, 8"[1]
Side-by-side comparison of selected equipment models
Attribute
Rainbow 4520Lam Research
Plasmalab 80 Plus RIEOxford Instruments
OEMLam ResearchOxford Instruments
CategoryEtchEtch
Wafer size8"8"
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyLam Research Rainbow 4520Oxford Instruments Plasmalab 80
Cited variants
  • Lam Rainbow 45XX Series[1]
—
Specifications
OEMLam Research[1]—
ModelLam Rainbow 4520[1]—
ConditionRefurbished and Upgraded[1]—
Chuck typeClamp; customized[1]—
Wafer sizeUp to 8 inch capability; customized[1]Small piece of wafer until max full 8 inches wafer[3]
ControllerAllwin21 PC with touch screen monitor[1]—
Operation modesMaintenance, Manual, Semi Automatic and Full Automatic[1]—
Wafer handlingFully automated, in-line, single-wafer plasma/RIE etching system[1]—
Gases1-6 or 1-8 lines with MFC; maximum 9 lines[1]—
EndpointDual endpoint 405nm/520nm; EOP optional[1]—
TypePlasma/RIE etching system[1]—
AutomationFully automated, in-line, single-wafer[1]—
Wafer Sizes6-inch or 8-inch[1]—
ElectrodeTop or/and bottom powered electrode plate[1]—
Electrode SpacingProgrammable[1]—
Wafer AlignmentAutomatic noncontact wafer alignment and placement[1]—
RF MatchUnique RF match networks located at upper and lower electrodes for programmable switching between plasma and RIE modes[1]—
Main UseOxide Etch (Lam Rainbow 45XX Series)[1]—
ControlComputer-controlled, manual or automatic control[1]—
Chamber TypeMain chamber, moving gap standard process kit[1]—
Chuck TypeClamp chuck; ESC chuck optional[1]—
Number of Gases1-6 or 1-8 lines MFC, maximum 9 lines[1]—
Typical GasesAr, CF4, CHF3, He, SF6, N2, NF3 (process dependent)[1]—
Endpoint DetectionDual endpoint 405nm/520nm EOP is optional[1]—
ChillerTCU LAM2080 Chiller module or equivalent is optional[1]—
Base Pressure≤ 5 mT[1]—
Chamber Leak Rate≤ 5 mT/min[1]—
ELL & XLL Leak Rate≤ 10 mT/min[1]—
Gap Set Point1 cm, tolerance ≤ 0.02 cm[1]—
Chiller Precision± 1 ℃[1]—
MFC/RF/DC Precision≤5% of set points[1]—
Particle (Bare-Si, RF-Off)< 50 @0.3um[1]—
Power208V, 50/60Hz, 3 phase, 5 wires, WYE, 30A(Max), 23(Norm) for Etcher[1]—
Physical Dimensions (Etcher)44"W x 54"D x 66"H, 1700 lbs[1]—
Physical Dimensions (RF Cart)22"W x 32"D x 44"H, 250 lbs[1]—
Physical Dimensions (TCU)23"W x 37"D x 55"H, 420 lbs[1]—
ExhaustEtcher Cabinet: Draw CFM 300, H2O 0.5, House, 4 inch Duct; Etcher Gas Panel: Draw CFM 75, H2O 0.5, Scrubbed, possible hazard, 2 inch Duct[1]—
Cooling WaterR.F. Cart: 2±0.2 GPM, 85±5 PSI, 14~35°C, 3/8" ID fittings, <200 u; TCU: 6±0.5 GPM, 11~26°C, 1/2" ID fittings, <200 u[1]—
Nitrogen40±10 PSI and 90±10 PSI, CDA can also be used for R.F. Cart[1]—
Thermal OutputEtcher: 3.4K carried by water, 3.4k by exhaust, 7k dispersed; RF Cart: 7K carried by water, 7k dispersed; TCU: 4K carried by water, 1k dispersed[1]—
Process Gases1/4" VCR fittings, <0.05u filter[1]—
Configuration—50/60 Hz[2]
Voltage—415 VAC, 3 Phase[2]
Full Load Amps—25.6 A[2]
Max Flow Rate Per Gas—100 sccm[2]
RF Generator—300 Watt 13.56 MHZ[2]
Table—Cool Down Only (No Heating)[2]
Typical Process Pressure—30 - 100 Mtorr[2]
Pumping System—Corrosion Resistant Turbo Molecular Pump with Rotary Pump[2]
Available Gases in Chamber—Ar, CF4, O2, CHF3, SF6, & He[2]
Phase—3 Phase[3]
Available gas in the chamber—Ar, CF4, O2, CHF3, SF6 & He.[3]
RF generator—300 Watt 13.56MHz[3]
Typical process pressure—30 – 100 mtorr[3]
Pumping system—Corrosion-resistant turbo-molecular pump with rotary pump[3]
Uniformity—5 - 10 % range[4]
Chamber Gases—Ar, CF4, O2, CHF3, SF6, He[2]
Table Type—Cool down only (no heating)[2]
Wafer Size—Small piece of wafer up to full 8 inches[3]
Frequency—50/60 Hz[2]
Available Gases—Ar, CF4, O2, CHF3, SF6, He[2]
Wafer Sizes Supported—2, 3, 4, 5, 6, 8 inch[3]
Dual Chamber Configuration—Available on some units[4]
PECVD Capability—9 inch plate, tested for 2-4 inch wafers[4]

Plan your fab

Building a Etch process? Get a complete equipment list.

Open the fab equipment planner →
Sources (5)Every fact above is drawn from these public sources
  1. [1]allwin21.comallwin21.com
  2. [2]inventory listing
  3. [3]inventory listing
  4. [4]inventory listing
  5. [5]inventory listing