Produced 1987–2007Varian 2100CD family
Research Quality: 40% complete
Varian2100CD
No photo available yet
  • Plate 01VARIAN -CLINAC - 2100CD

    KENSINGTON MEDICALWatch on YouTube
  • Plate 02Six minute saws #3 Husqvarna 2100CD

    Derek's stuffWatch on YouTube
  • Plate 03Husqvarna 2100CD with velocity stack and 090 muffler

    Fabz Acres - East Coast Muscle Saws Watch on YouTube
  • Plate 04Husqvarna 2100cd 36 inch bar

    Kyle’s Custom sawsWatch on YouTube
  • Plate 05Freebie Husqvarna 2100CD chainsaw from 1982! #orange #runner #compression

    JJD's Vintage ChainsawsWatch on YouTube
  • Plate 06Husqvarna 2100CD 99cc BEAST - slowly dialing in the carb 😎

    Fabz Acres - East Coast Muscle Saws Watch on YouTube

How it works

The Varian 2100CD offers photon energy configurations of 6 MV and up to 10, 15, 18, or 25 MV depending on the variant. For photon mode, the maximum dose rate is 600 monitor units per minute. Electron beam energies are also available with a maximum dose rate of 1000 monitor units per minute.[1]

The Varian 2100CD can be equipped with either an 80-leaf multi-leaf collimator (MLC) covering a maximum field size of 40 by 40 centimeters, or a 120-leaf MLC of the same field size. The 120-leaf version uses 5-millimeter leaf width in the central 20 centimeters and 10-millimeter width in the outer 20 centimeters. An optional on-board imager (OBI) enables kV imaging and cone-beam CT for image-guided radiation therapy.[1]

Where it fits in the process flow

The Varian 2100CD supports 3D conformal radiation therapy and intensity-modulated radiation therapy (IMRT). Optional capabilities include stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) when fitted with cones or a micro-MLC. Volumetric modulated arc therapy (VMAT) is available only if the optional OBI system is installed.[1]

Applications

With its optional stereotactic radiosurgery capability, the Varian 2100CD can deliver highly focused radiation to small intracranial lesions using cones or a micro-MLC. The optional OBI system enables image-guided radiation therapy (IGRT) by acquiring kV X-ray images or cone-beam CT scans immediately before or during treatment.[1]

What do the numbers mean?

Dimensions & facilities1

Multi-Leaf Collimator (MLC) options
80 (Field size 40x40cm); 120 MLC (Field size 40x40cm, Central 20cm of field - 5mm leaf width, Outer 20cm of field - 10mm leaf width)[1]
Accurate?

Configuration & options8

Power Source
Klystron[1]
Accurate?
Electron Energies
Yes[1]
Accurate?
Max Dose Rate Electrons
1000 MU/min[1]
Accurate?
Default photon dose rate
600 MU/min[1]
Accurate?
Portal Imager (EPID) options
LC250, aS500, aS1000 (optional)[1]
Accurate?
Cone-Beam CT
Only with OBI[1]
Accurate?
VMAT
Only with OBI[1]
Accurate?
Stereotactic Radiosurgery
Optional Cones or mMLC[1]
Accurate?

Vintage & configurations

  1. 1987Production start[1]

    Production start year for the 2100C/2100CD series.

  2. 2007Production end[1]

    Production end year for the 2100C/2100CD series.

Interested in this tool?
Need help with this tool?Embed spec card

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Not publicly documented

The following facts about the 2100CD are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented variants, configuration options, or revision breakpoints of the 2100CD are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 2100CD are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 2100CD are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 2100CD is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 2100CD are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (1)Every fact above is drawn from these public sources
  1. [1]oncologysystems.com — oncologysystems.comoncologysystems.com
Was this page accurate?

Last updated Sep 22, 2026.

Compare with similar tools

View all →