The TESCAN S8000X is a FIB/SEM combining a plasma-source focused ion beam microscope and a high-resolution (BrightBeam) scanning electron microscope. The TESCAN S8000X uses a Xe+ ion plasma source capable of generating a focused beam up to 1 uA. The TESCAN S8000X includes a cryogenic stage and a sample transfer loadlock allowing work down to -160 C.[1]

TescanS8000X
No photo available yet

What it is

The TESCAN S8000X is a versatile instrument for the characterization of materials. It combines a plasma-source focused ion beam microscope and a high-resolution BrightBeam scanning electron microscope.[1]

The instrument is equipped with advanced analytical capabilities, including Time-of-Flight Secondary Ion Mass Spectrometery and an Energy Dispersive x-ray spectrometer. It also includes a cryogenic stage, a sample transfer loadlock, and a cryogenic Kleindiek nanomanipulator.[1]

How it works

The focused ion beam microscope uses a Xe+ ion plasma source. The Xe plasma can generate a focused beam up to 1 uA, which allows very high milling rates and does not lead to deleterious ion implantation in the same way that Ga+ ions do.[1]

The BrightBeam SEM is a field-free, ultra-high resolution electron microscope whose optics allow improved resolution, even at low energies. This improves imaging of non-conducting samples.[1]

Time-of-Flight Secondary Ion Mass Spectrometery detects ions emitted from the sample, allowing chemical characterization. An Energy Dispersive x-ray spectrometer provides additional, complementary chemical characterization.[1]

Where it fits in the process flow

The instrument is used for characterization of materials. Its cryogenic stage and sample transfer loadlock allow work down to -160 C or introduction of frozen samples into the tool to be milled.[1]

A cryogenic Kleindiek nanomanipulator enables users to interact with the sample in-situ as well as lift-out frozen sections for subsequent TEM analysis.[1]

Applications

The BrightBeam SEM improves imaging of non-conducting samples. ToF-SIMS is especially useful in detecting light elements, including the discrimination of hydrogen and deuterium.[1]

The Xe plasma focused beam allows very high milling rates. The instrument is also equipped for additional, complementary chemical characterization with EDS.[1]

  • Materials characterization
  • Chemical characterization
  • Detecting light elements including discrimination of hydrogen and deuterium
  • Work with frozen samples
  • In-situ sample interaction
  • Lift-out of frozen sections for subsequent TEM analysis

What do the numbers mean?

Vacuum & pumping3

Cryogenic capability
Cryogenic stage and sample transfer loadlock allowing work down to -160 C or introduction of frozen samples[1]
Accurate?
Nanomanipulator
Cryogenic Kleindiek nanomanipulator for in-situ interaction and lift-out of frozen sections for subsequent TEM analysis[1]
Accurate?
Cryogenic stage temperature range
down to -160 C[1]
Accurate?

Optics & imaging3

Instrument type
Plasma-source focused ion beam microscope and high-resolution BrightBeam scanning electron microscope[1]
Accurate?
Electron microscope optics
Field-free, ultra-high resolution optics with improved low-energy imaging[1]
Accurate?
Electron source type
BrightBeam SEM, field-free, ultra-high resolution[1]
Accurate?

Configuration & options8

Ion source
Xe+ ion plasma source[1]
Accurate?
Focused beam current
Up to 1 uA[1]
Accurate?
Milling rate
Up to 50X faster than prior Ga+ ion technology[1]
Accurate?
Analytical capability
Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS)[1]
Accurate?
Analytical capability
Energy Dispersive x-ray spectrometer (EDS)[1]
Accurate?
Ion source type
Xe+ ion plasma source[1]
Accurate?
Maximum focused beam current
1 uA[1]
Accurate?
Analytical capabilities
ToF-SIMS and EDS[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Cryogenic capabilityCryogenic stage and sample transfer loadlock allowing work down to -160 C or introduction of frozen samples[1]
  • NanomanipulatorCryogenic Kleindiek nanomanipulator for in-situ interaction and lift-out of frozen sections for subsequent TEM analysis[1]
  • Cryogenic stage temperature rangedown to -160 C[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of ion source does the FIB in the TESCAN S8000X use?

The focused ion beam uses a xenon (Xe⁺) plasma source.[1]

What is the maximum beam current the FIB can deliver?

The Xe plasma source can generate a focused beam up to 1 μA.[1]

How much faster is the milling rate compared to gallium-ion FIBs?

The milling rate can be up to 50 times faster than prior Ga⁺ ion technology.[1]

What analytical instruments are integrated with the S8000X?

The system includes a time-of-flight secondary ion mass spectrometer and an energy-dispersive X-ray spectrometer.[1]

What is the minimum temperature achievable with the cryogenic stage?

The cryogenic stage can cool the sample down to -160 °C.[1]

What is the special feature of the scanning electron microscope in this instrument?

The SEM, called BrightBeam, is a field-free, ultra-high-resolution column that provides improved resolution even at low electron energies.[1]

Not publicly documented

The following facts about the S8000X are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the S8000X are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the S8000X are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the S8000X are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the S8000X are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the S8000X is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (1)Every fact above is drawn from these public sources
  1. [1]nano.upenn.edu — nano.upenn.edunano.upenn.edu
Was this page accurate?

Last updated Sep 21, 2026.

Compare with similar tools

View all →