The Perkin Elmer LC 300 Liquid Chromatography is a liquid chromatography system. The Perkin Elmer LC 300 Liquid Chromatography supports HPLC and UHPLC applications. The Perkin Elmer LC 300 Liquid Chromatography can be configured with detectors including PDA, MWD, UV/Vis, FL, and RI.[1][2][3]

LC 300 Liquid Chromatography — Inventory photo
Fig. 01LC 300 Liquid ChromatographyInventory photo[1]

Vacuum

Solvent Delivery / Pump Compartment[1]

Optics

Photodiode Array Detector[1]

What it is

The Perkin Elmer LC 300 is a liquid chromatography system.[1][2][4][3]

The LC 300 platform is a high-performance liquid chromatography and ultrahigh-performance liquid chromatography system.[2][3]

How it works

The LC 300 family includes an autosampler, a solvent delivery or pump compartment, and a photodiode array detector.[1][4]

The LC 300 platform supports binary and quaternary high-pressure pump systems, built-in column oven capability, integrated solvent containment, and a range of detector options including PDA, multi-wavelength UV/Vis, single-wavelength UV/Vis, fluorescence, and refractive index detection.[2][3]

The LC 300 platform supports instrument control and data acquisition through SimplicityChrom and other chromatography data system platforms.[2][3]

Where it fits in the process flow

The LC 300 is positioned for laboratory chromatography work that includes high-throughput requirements and challenging chromatographic separations.[3]

What do the numbers mean?

Vacuum & pumping4

Solvent Delivery / Pump Compartment[1]
Accurate?
Pump options
Binary and quaternary high-pressure pump systems[2]
Accurate?
Autosampler pressure
10,000 psi or 18,000 psi[3]
Accurate?
Solvent delivery pressure
10,000 psi or 18,000 psi[3]
Accurate?

Gas & chemistry1

Flow channels
Up to four solvents with binary solvent delivery[3]
Accurate?

Optics & imaging6

Photodiode Array Detector[1]
Accurate?
Detectors
PDA, Multi-Wavelength UV/Vis, Single wavelength UV/Vis, FL, and RI[3]
Accurate?
Autosampler features
UHPLC Autosampler; built-in column oven; high-visibility color LCD screen[1]
Accurate?
Column oven
Integrated column oven with preheater[3]
Accurate?
Column length support
Single column up to 150 mm in length[3]
Accurate?
Column compartment temperature range
Ambient +5 °C to 60 °C[3]
Accurate?

Control & software1

Data/control communication
Ethernet communication[3]
Accurate?

Configuration & options6

With Perkin Elmer LC 300:[1]
Accurate?
UHPLC Autosmapler[1]
Accurate?
Platform
Liquid chromatography system[1]
Accurate?
Compatibility
HPLC and UHPLC[2]
Accurate?
Sample tray temperature range
4 °C to 40 °C with Peltier option[3]
Accurate?
Injection volume
As low as 1 μL[3]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • ConfigurationSolvent Delivery / Pump Compartment[1]
  • Pump optionsBinary and quaternary high-pressure pump systems[2]
  • Autosampler pressure10,000 psi or 18,000 psi[3]
  • Solvent delivery pressure10,000 psi or 18,000 psi[3]
  • Flow channelsUp to four solvents with binary solvent delivery[3]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What chromatography modes does the LC 300 platform support?

The LC 300 platform supports HPLC and UHPLC operation.[2][3]

What detector types are available on the LC 300 platform?

The LC 300 platform offers PDA, multi-wavelength UV/Vis, single-wavelength UV/Vis, fluorescence, and refractive index detector options.[2][3]

Does the LC 300 include an autosampler display?

The LC 300 autosampler includes a high-visibility color LCD screen that shows system status information.[2][3]

What software platforms can control the LC 300?

The LC 300 is controlled by PerkinElmer SimplicityChrom and supports other chromatography data system platforms.[2][3]

Not publicly documented

The following facts about the LC 300 Liquid Chromatography are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the LC 300 Liquid Chromatography are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the LC 300 Liquid Chromatography are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the LC 300 Liquid Chromatography are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the LC 300 Liquid Chromatography are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the LC 300 Liquid Chromatography is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]labonline.com.au — labonline.com.aulabonline.com.au
  3. [3]pepolska.pl — pepolska.plpepolska.pl
  4. [4]LC 300 Liquid Chromatography — Perkin Elmer | Specs, Sourcing & Service | Waferpedia — waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 7, 2026.

Compare with similar tools

View all →