Waferpedia

Nordson

4000 TPAXY

Packaging & BondingNordson 4000 TPAXY family
Research Quality: 50% complete
4000 TPAXY — Inventory photo
Fig. 014000 TPAXYInventory photo[2]

Power

110/240 VAC, Single Phase[2]

Performance

Precision Vise Fixture[2]

Optics

Binocular Microscope, 0.5X Objective[2]

What it is

The Nordson 4000 TPAXY is an automated bond-testing system from Nordson/Dage.[2][1]

How it works

General reference — not yet source-verified

Bond testers apply controlled forces to a bonded interface and measure the force required to break the bond. Common tests include wire bond pull, ball shear, wedge pull, and die shear.

Where it fits in the process flow

General reference — not yet source-verified

In semiconductor packaging, bond testers are used in quality control after wire bonding, flip-chip bonding, or die attach steps. Testing is performed before encapsulation or further assembly to ensure interconnect integrity.

What do the numbers mean?

Power & electrical2

Power
110/240 VAC, Single Phase[2]
Accurate?
Frequency
50/60 Hz[2]
Accurate?

Optics & imaging1

Microscope Objective
Binocular Microscope, 0.5X Objective[2]
Accurate?

Performance1

Fixture
Precision Vise Fixture[2]
Accurate?

Control & software2

Computer
Dell OptiPlex 7020 with Intel Core i5 Processor[2]
Accurate?
Ionizing-Air Blowers
Two SIMCO Aerostat PC Ionizing-Air Blowers[2]
Accurate?

Configuration & options8

Power Consumption
250 VA[2]
Accurate?
Short-Circuit Current Protection
28 A[2]
Accurate?
Maximum Motor Load
2 A[2]
Accurate?
Working Distance
165 mm[2]
Accurate?
Test-Head Cartridge
Nordson DAGE DS100[2]
Accurate?
Stage Type
Motorized X-Y Stage[2]
Accurate?
Specimen Platform
Rotary Pneumatic Specimen Platform[2]
Accurate?
Vintage
2016[1]
Accurate?

Observed configurations

How individual machines were equipped when they appeared on the secondary market — as listed, per unit. These describe one specific machine, not the model in general.

Unit as listed[2]

  • Additional Fixture
  • Pressure Gauges
  • Pneumatic Connections
  • Electrical Connections
  • Additional Rotary Specimen Platform
  • 110/240 VAC, Single Phase
  • Frequency: 50/60 Hz
  • Power Consumption: 250 VA
  • Short-Circuit Current Protection: 28 A
  • Maximum Motor Load: 2 A
  • Nordson DAGE DS100 Test-Head Cartridge
  • Binocular Microscope
  • Working Distance: 165 mm
  • Motorized X-Y Stage
  • Rotary Pneumatic Specimen Platform
  • Precision Vise Fixture
  • Positioning Controls
  • Integrated Keyboard
  • Operator Wrist Rests
  • Adjustable Illumination
  • Dell OptiPlex 7020 Computer
  • Intel Core i5 Processor
  • Connecting Cables

Vintage & configurations

  1. 2016Manufacture year[1]

    Manufactured in the United Kingdom in 2016.

Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Power110/240 VAC, Single Phase[2]
  • Frequency50/60 Hz[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What are the electrical power requirements for the Nordson 4000 TPAXY?

The system operates on 110/240 VAC, single phase, 50/60 Hz, with a power consumption of 250 VA.[2]

Does the 4000 TPAXY include a motorized stage?

Yes, the system is equipped with a motorized X-Y stage for automated positioning of the device under test.[2]

Not publicly documented

The following facts about the 4000 TPAXY are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented variants, configuration options, or revision breakpoints of the 4000 TPAXY are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 4000 TPAXY are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 4000 TPAXY are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 4000 TPAXY is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 4000 TPAXY are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]bidspotter.com — bidspotter.combidspotter.com
  2. [2]Inventory photo
  3. [3]Equipment inventory listing
Was this page accurate?

Last updated Sep 23, 2026.

Compare with similar tools

View all →