Nikon

The Nikon Eclipse LV 100 POL is a polarizing light microscope designed for transmitted (diascopic) and reflected (episcopic) polarized light microscopy. The microscope is intended primarily for the observation and photomicrography of stones, rocks, minerals, and high-polymer materials. The Eclipse LV 100 POL belongs to Nikon's Eclipse family of upright microscopes and is classified as a metrology and inspection instrument.[5][3][4]
Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.
Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.
No research found yet — worked with this tool? Share what you know.
The Eclipse LV 100 POL uses a 12V-50W halogen lamp with a fly-eye lens design. A built-in DC transformer is standard, and a 12V-100W type is optional with an external power supply. NCB11 and ND8 filters are built-in.[4]
The focusing stroke is 30 mm. Coarse adjustment is 14 mm per rotation, fine adjustment is 0.1 mm per rotation, and the minimum reading is 1 µm increments.[4]
The microscope uses CFI P Achromat objectives at 4x, 10x, 20x, 40x, and 100x, and CFI LU Plan Fluor EPI P objectives at 5x, 10x, 20x, 50x, and 100x. The latter are made with eco-glass free of lead and arsenic.[4]
Yes. Diascopic (transmitted) and episcopic (reflected) polarized light observations are possible. The LV-UEPI universal epi-illuminator is required for episcopic illumination, and a changeover switch on the microscope body selects between the two modes.[3][4]
The following facts about the Eclipse LV 100 POL Polarizing Light are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.
No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Eclipse LV 100 POL Polarizing Light are on record.
Answerable by: OEM historical records or a trade-press announcement
No publicly documented variants, configuration options, or revision breakpoints of the Eclipse LV 100 POL Polarizing Light are on record.
Answerable by: an OEM product catalog or an engineer who ordered or specified the tool
The control-system platform and OS era of the Eclipse LV 100 POL Polarizing Light are not on record.
Answerable by: an engineer who operated it or OEM installation records
No publicly documented failure modes or field errata for the Eclipse LV 100 POL Polarizing Light are on record.
Answerable by: a field service engineer, process engineer, or maintenance technician
The process node or technology generation of the Eclipse LV 100 POL Polarizing Light is not on record.
Answerable by: an OEM datasheet or a fab qualification report
No research found yet — worked with this tool? Share what you know.
Last updated Oct 7, 2026.