Waferpedia

Chroma

61604

Chroma 61604 family
Research Quality: 30% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Chroma 61604 is a programmable AC power source in the 61600 series. The Chroma 61604 delivers 2000 VA of AC power and has a voltage range of 0-300V and a frequency range of 15-1000Hz.[1][2]

Chroma61604
No photo available yet

Power

150V/300V/Auto[1]

Performance

0.2%+0.2%F.S.[1]

Optics

0.1W[1]

How it works

The Chroma 61600 series employs advanced pulse-width modulation (PWM) technology and a power factor correction circuit to achieve high efficiency and clean output waveforms. A digital signal processor (DSP) is used to program voltage waveforms and to perform precision measurements. The series includes a 16-bit measurement circuit for parameters such as RMS voltage, RMS current, true power, power factor, peak current, inrush current, current crest factor, apparent power, and reactive power.[1][3]

The instrument provides an external analog input that can amplify signals from an arbitrary signal generator, enabling it to simulate complex or field-recorded waveforms. Output voltage amplitude can also be controlled by an external DC level. Remote control is available via GPIB, RS-232, or analog programming interfaces. The unit includes a liquid crystal display (LCD) and a rotary knob for front-panel operation.[1][3]

The Chroma 61604 incorporates full protection against over-power, over-current, over-voltage, and over-temperature conditions. A power-on self-diagnosis routine verifies the instrument's integrity at startup.[1]

Applications

The Chroma 61600 series is intended for commercial, avionics, and military applications requiring clean AC power. Typical uses include testing power supplies, power electronics, and equipment that must operate from various AC line voltages and frequencies.[1][4]

The 61604 is specifically suited for inrush current testing due to its ability to deliver up to six times peak current relative to the maximum rated current. The programmable turn-on and turn-off phase angle control enables precise inrush testing. The AC+DC output mode facilitates testing of DC offset effects or DC bias conditions.[1][3]

What do the numbers mean?

Power & electrical42

Voltage Range/Phase
150V/300V/Auto[1]
Accurate?
Resolution
0.1V[1]
Accurate?
Distortion
0.3% @ 50/60Hz; 1% @ 15~1kHz[1]
Accurate?
Max. Current/Phase r.m.s.
16A/8A (150V/300V)[1]
Accurate?
Max. Current/Phase peak
96A/48A (150V/300V)[1]
Accurate?
Frequency Range
DC, 15~1kHz[1]
Accurate?
Frequency Resolution
0.01 Hz[1]
Accurate?
DC Voltage
212V/424V[1]
Accurate?
DC Current
8A/4A (212V/424V)[1]
Accurate?
Input Voltage Range
1Ø 100~240V±10%VLN[1]
Accurate?
Input Current
28A Max. @ 90V[1]
Accurate?
Measurement Voltage Range
150V/300V[1]
Accurate?
Measurement Voltage Accuracy
0.2%+0.2%F.S.[1]
Accurate?
Measurement Voltage Resolution
0.1V[1]
Accurate?
Voltage Range (AC)
0 – 300 VAC[1]
Accurate?
Voltage Range (DC)
212 V / 424 V[1]
Accurate?
Frequency Range
DC, 15 Hz – 1 kHz[1]
Accurate?
Max RMS Current (150V range)
16 A[1]
Accurate?
Max RMS Current (300V range)
8 A[1]
Accurate?
Max Peak Current (150V range)
96 A[1]
Accurate?
Max Peak Current (300V range)
48 A[1]
Accurate?
Voltage Accuracy
0.2% + 0.2% F.S.[1]
Accurate?
Total Harmonic Distortion
< 0.3% at 50/60 Hz; 1% typical 15-1 kHz[1]
Accurate?
Input Frequency
47 – 63 Hz[1]
Accurate?
Input Current (max)
28 A at 90 V[1]
Accurate?
Output Voltage Range
0 to 150 V / 0 to 300 V / Auto[1]
Accurate?
Output Frequency Range
15 Hz to 1000 Hz (DC included)[1]
Accurate?
Max Output Current (RMS)
16 A at 150 V / 8 A at 300 V[1]
Accurate?
Max Output Current (Peak)
96 A at 150 V / 48 A at 300 V[1]
Accurate?
Output Distortion
0.3% at 50/60 Hz; 1% at 15–1000 Hz (typical)[1]
Accurate?
DC Output Voltage
212 V / 424 V[1]
Accurate?
Input Voltage Range
100–240 V ±10% (single phase)[1]
Accurate?
Max Input Current
28 A at 90 V[1]
Accurate?
Voltage Accuracy
0.2% + 0.2% of full scale[1]
Accurate?
Protections
OPP (over‑power), OCP (over‑current), OVP (over‑voltage), OTP (over‑temperature)[1]
Accurate?
Voltage Range
0-150 V / 0-300 V / Auto[1]
Accurate?
Voltage Resolution
0.1 V[1]
Accurate?
Distortion
0.3% @ 50/60 Hz; 1% @ 15-1 kHz (typical)[1]
Accurate?
Max. Output RMS Current (150 V / 300 V)
16 A / 8 A[1]
Accurate?
Max. Output Peak Current (150 V / 300 V)
96 A / 48 A[1]
Accurate?
DC Output Current (212 V / 424 V)
8 A / 4 A[1]
Accurate?
Input Voltage Range
1-phase 100-240 V ±10% VLN[1]
Accurate?

Optics & imaging1

Power Resolution
0.1W[1]
Accurate?

Performance8

Accuracy
0.2%+0.2%F.S.[1]
Accurate?
Frequency Accuracy
0.15%[1]
Accurate?
Measurement Current Accuracy (r.m.s.)
0.4%+0.3%F.S.[1]
Accurate?
Measurement Current Accuracy (peak)
0.4%+0.6%F.S.[1]
Accurate?
Power Accuracy
0.4%+0.4%F.S.[1]
Accurate?
Measurement RMS Current Accuracy
0.4% + 0.3% F.S.[1]
Accurate?
Measurement Peak Current Accuracy
0.4% + 0.6% F.S.[1]
Accurate?
Measurement Power Accuracy
0.4% + 0.4% F.S.[1]
Accurate?

Control & software1

Remote Interfaces
GPIB, RS-232, Analog Programming (APG); optional LAN/USB[1]
Accurate?

Dimensions & facilities9

Dimensions (H x W x D)
133.35 x 482.6 x 569.5 mm[1]
Accurate?
Weight
21 kg[1]2 sources
Accurate?
Dimensions (H x W x D)
133.35 x 482.6 x 569.5 mm (5.25 x 19 x 22.42 in)[1]
Accurate?
Weight
21 kg (44.05 lbs)[3]
Accurate?
Dimensions (W × H × D)
483 × 134 × 610 mm[2]
Accurate?
Dimensions (H x W x D) – Datasheet
133.35 x 482.6 x 569.5 mm[1]
Accurate?
Weight – Datasheet
20 kg[1]
Accurate?
Dimensions (W x H x D) – User Manual
483 x 134 x 610 mm[2]
Accurate?
Weight – User Manual
21 kg[2]
Accurate?

Configuration & options24

Output Rating - AC Power/Phase
2000VA[1]
Accurate?
Line Regulation
0.1%[1]
Accurate?
Load Regulation
0.2%[1]
Accurate?
DC Output Power
1000W[1]
Accurate?
Input Frequency Range
47~63Hz[1]
Accurate?
Input Power Factor
0.98 Min.[1]
Accurate?
Measurement Current Range (peak)
96A[1]
Accurate?
Operating Temperature
0~40°C[1]
Accurate?
Storage Temperature
-40~+85°C[1]
Accurate?
Safety & EMC
CE (include EMC & LVD)[1]
Accurate?
AC Power Rating
2000 VA[1]
Accurate?
DC Power Rating
1000 W[1]
Accurate?
Output Phases
1[1]
Accurate?
Input Power Factor
0.98 min at full load[1]
Accurate?
Safety & EMC
CE (EMC & LVD)[1]
Accurate?
Output Power
2000 VA (2 kVA)[1]
Accurate?
Number of Phases
1[1]
Accurate?
DC Output Current
8 A / 4 A[1]
Accurate?
Input Power Factor
0.98 minimum (full load)[1]
Accurate?
Operating Temperature Range
0 to 40 °C[1]
Accurate?
Storage Temperature Range
-40 to +85 °C[1]
Accurate?
Max Crest Factor
6:1[1]
Accurate?
AC Output Power
2000 VA[1]
Accurate?
Storage Temperature
-40 to +85 °C[1]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
61601——500VA output powerchromausa.com[1]
61602——1000VA output powerchromausa.com[1]
61603——1500VA output powerchromausa.com[1]
61605——4000VA output power, 3-phase input, larger dimensionschromausa.com[1]
61604——2000 VAchromausa.com[1]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Voltage Range/Phase150V/300V/Auto[1]
  • Resolution0.1V[1]
  • Distortion0.3% @ 50/60Hz; 1% @ 15~1kHz[1]
  • Max. Current/Phase r.m.s.16A/8A (150V/300V)[1]
  • Max. Current/Phase peak96A/48A (150V/300V)[1]
  • Frequency RangeDC, 15~1kHz[1]
  • Frequency Resolution0.01 Hz[1]
  • DC Voltage212V/424V[1]
  • DC Current8A/4A (212V/424V)[1]
  • Input Voltage Range1Ø 100~240V±10%VLN[1]
  • Input Current28A Max. @ 90V[1]
  • Measurement Voltage Range150V/300V[1]
  • Measurement Voltage Accuracy0.2%+0.2%F.S.[1]
  • Measurement Voltage Resolution0.1V[1]
  • Voltage Range (AC)0 – 300 VAC[1]
  • Voltage Range (DC)212 V / 424 V[1]
  • Frequency RangeDC, 15 Hz – 1 kHz[1]
  • Max RMS Current (150V range)16 A[1]
  • Max RMS Current (300V range)8 A[1]
  • Max Peak Current (150V range)96 A[1]
  • Max Peak Current (300V range)48 A[1]
  • Voltage Accuracy0.2% + 0.2% F.S.[1]
  • Total Harmonic Distortion< 0.3% at 50/60 Hz; 1% typical 15-1 kHz[1]
  • Input Frequency47 – 63 Hz[1]
  • Input Current (max)28 A at 90 V[1]
  • Output Voltage Range0 to 150 V / 0 to 300 V / Auto[1]
  • Output Frequency Range15 Hz to 1000 Hz (DC included)[1]
  • Max Output Current (RMS)16 A at 150 V / 8 A at 300 V[1]
  • Max Output Current (Peak)96 A at 150 V / 48 A at 300 V[1]
  • Output Distortion0.3% at 50/60 Hz; 1% at 15–1000 Hz (typical)[1]
  • DC Output Voltage212 V / 424 V[1]
  • Input Voltage Range100–240 V ±10% (single phase)[1]
  • Max Input Current28 A at 90 V[1]
  • Voltage Accuracy0.2% + 0.2% of full scale[1]
  • ProtectionsOPP (over‑power), OCP (over‑current), OVP (over‑voltage), OTP (over‑temperature)[1]
  • Voltage Range0-150 V / 0-300 V / Auto[1]
  • Voltage Resolution0.1 V[1]
  • Distortion0.3% @ 50/60 Hz; 1% @ 15-1 kHz (typical)[1]
  • Max. Output RMS Current (150 V / 300 V)16 A / 8 A[1]
  • Max. Output Peak Current (150 V / 300 V)96 A / 48 A[1]
  • DC Output Current (212 V / 424 V)8 A / 4 A[1]
  • Input Voltage Range1-phase 100-240 V ±10% VLN[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

Can multiple 61604 units be combined for three-phase output?

Yes, up to three 61600 series units can be combined to produce a three-phase power output.[1][4]

Not publicly documented

The following facts about the 61604 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 61604 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the 61604 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 61604 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 61604 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 61604 are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (5)Every fact above is drawn from these public sources
  1. [1]chromausa.com — chromausa.comchromausa.com
  2. [2]assets.testequity.com — assets.testequity.comassets.testequity.com
  3. [3]testequipment.center — testequipment.centertestequipment.center
  4. [4]TestEquity: Chroma 61604 AC Power Source, 2kVA, 15-1kHz, 1 Phase, 150V/300V/Auto, 61600 Series — testequity.comtestequity.com
  5. [5]Equipment inventory listing
Was this page accurate?

Last updated Sep 30, 2026.

Compare with similar tools