Comparison ledger
Lam Research SEZ SP 203, Thermo Fisher 1300 Series Safety, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | SEZ SP 203Lam Research | 1300 Series SafetyThermo Fisher |
|---|---|---|
| OEM | Lam Research | Thermo Fisher |
| Category | Wet Processing / Clean | Wet Processing / Clean |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | — |
| Lifecycle | — | — |
| Lifecycle milestones | 1998 Vintage | 2026 Third-party support only |
| Control system | — | — |
| Generation | — | — |
| Family | Lam Research SEZ SP 203 | Thermo Fisher 1300 |
| Cited variants |
| — |
| Specifications | ||
| Configuration | 200-208 V[2] | Class II[4] |
| Phase | 3 Phase[2] | — |
| Pinless chuck | 6 Inch[2] | — |
| Software | Major Version 117[2] | — |
| Cabinet 1 | Main tank and Buffer tank[2] | — |
| Cabinet 2 | Main tank and Buffer tank[2] | — |
| Cabinet 3 | Main tank[2] | — |
| Modifications | FFU controller; 1 cabinet drain box repaired[2] | — |
| Manufacturer | Lam Research[3] | — |
| Category | Wet Processing / Clean[3] | — |
| Wafer size | 6 inch[2] | — |
| Power | 200-208 V[2] | — |
| Frequency | 50/60 Hz[2] | — |
| Wafer handling | 6 Inch Bernoulli Handling[2] | — |
| Chuck | Pinless chuck: 6 Inch[2] | — |
| Vacuum exhaust | Exhaust Up[3] | — |
| Chemistry cabinets | 3 Chemistry Cabinets[3] | — |
| Software major version | 117[2] | — |
| Software minor version | 2015.08.21[2] | — |
| GEM version | GEM 5.8[2] | — |
| Known problems | Keyboard switching; Voltage fluctuations[2] | — |
| Cabinet type | — | Class II, Type A2 biological safety cabinet[5] |
| Airflow compensation | — | SmartFlow airflow compensation system[5] |
| Motors | — | Dual DC motors[5] |
| Front window design | — | SmartClean front window design[5] |
| Control panel | — | Intuitive control panel with constant readout of downflow and inflow velocities and filter reserve status[5] |
| UV light | — | Programmable UV light[5] |
| SmartPort | — | SmartPort convenience for routing tubing and cables through the side walls[5] |
| Available widths | — | 3-foot, 4-foot, 5-foot, and 6-foot sizes[5] |
| Front opening choices | — | 8-inch or 10-inch front opening[5] |
| Filter specification | — | H14 HEPA filters, EN 1822, 99.995% @ MPPS[6] |
| Certification | — | NSF/ANSI 49, UL, CE[6] |
| Service valves | — | Up to 6 total, 3 on each side wall[6] |