Attribute
0020 12458 PartApplied Materials
800Oxford Instruments
OEMApplied MaterialsOxford Instruments
CategoryDepositionDeposition
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyApplied Materials 0020 12458 PartOxford Instruments 800
Cited variants—
  • 800 Plus (Plasmalab800Plus)[1]
Specifications
ConfigurationInsulator,Side Match,Hdp-Cvd Ultima Plus[2]—
Asset number146526[2]—
MakeApplied Materials[2]—
Model0020 12458[2]—
Table diameter—380 mm or 460 mm[1]
Wafer capacity (300 mm)—1[1]
Process configurations—PECVD, RIE, RIE/PE dual mode, ICP[1]
Substrate temperature range—up to 400 °C[1]
Cryogenic temperature option—down to -150 °C[1]
End-point detection—Laser interferometry or optical emission spectrometry (OES)[1]
Gas line options—4, 8, or 12 lines[1]
RF frequency—13.56 MHz[3]
Low frequency range—100–350 kHz[3]
Deposition rate (SiNx, NH3-free process)—up to 20 nm/min[3]
Process gases—SiH4, NH3, N2O, CH4, N2, Ar, He, CF4, O2[3]
Mains power—50/60 Hz[3]
Stress control—Pulsed HF/LF power mixing[3]