Waferpedia

Comparison ledger

Candela CS 20 V Surface Analyzerversus12 Lapper

KLA Candela CS 20 V Surface Analyzer, Lapmaster 12 Lapper, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
12 LapperLapmaster
OEMKLALapmaster
CategoryCMPCMP
Wafer size2"—
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyKLA Candela CS 20—
Cited variants
  • Candela CS 20 V[1]
—
Specifications
ConfigurationViolet Laser (405nm, 25mW)[1]—
PhaseLaser: 405 nm, 25 mW diode - Spot size: 5 × 6 µm Detection modes: - Scattered light - Specular reflection - Phase shift - Surface topography[2]1[4]
Wafer sizeWafer Handling: - Sizes: 2", 3", 4", 5", 6", 8" - Thickness: 0.2–1.1 mm - Automatic robotic transfer - Cassette-to-cassette operation[2]—
Laser wavelength405 nm[2]—
Laser power25 mW[2]—
Spot size5 × 6 µm[2]—
Detection modesScattered light, specular reflection, phase shift, surface topography[2]—
Wafer sizes supported2", 3", 4", 5", 6", 8"[2]—
Wafer thickness range0.2–1.1 mm[2]—
Particle detection threshold0.08 µm (PSL equivalent)[2]—
Particle detection rate≥95% on polished wafers[2]—
Scratch detection dimensionsLength: 100 µm, Width: 0.1 µm, Depth: 50 Å[2]—
Pit/Bump detection dimensionsDiameter: 20 µm, Depth: 50 Å[2]—
Stain detection dimensionsDiameter: 20 µm, Film thickness: 10 Å[2]—
Topography vertical resolution1 Å[2]—
Wafer handlingAutomatic robotic transfer, cassette-to-cassette[2]—
Operating systemWindows XP[3]—
Power supply230 VAC 50/60 Hz[3]—
Cleanroom environmentInternal class 10[3]—
Wafer sizes2", 3", 4", 5", 6", 8"[2]—
Particle detection minimum size0.08 µm (PSL equivalent)[2]—
Particle detection rate (polished wafers)≥95%[2]—
Scratch detection minimum length100 µm[2]—
Scratch detection minimum width0.1 µm[2]—
Scratch detection minimum depth50 Å[2]—
Pit/Bump detection minimum diameter20 µm[2]—
Pit/Bump detection minimum depth50 Å[2]—
Stain detection minimum diameter20 µm[2]—
Stain detection minimum film thickness10 Å[2]—
Vintage2012[1]—
MakeKLA[1]—
ModelCandela CS 20 V[1]—
Laser405 nm, 25 mW diode[2]—
Particle detectionDown to 0.08 µm (PSL equivalent); ≥95% detection rate (on polished wafers)[2]—
Vertical resolution1 Å[2]—
Control systemWindows XP operating system[3]—
Outside plate diameter—12 inches[4]
Lapping Speed Range—0 to 60 rpm[5]
Wafer Size Compatibility—4 inches or smaller[4]
Input Voltage—110 V[4]
Frequency—60 Hz[4]
Number of Rings—3[4]
Number of Weights—3[4]
Includes Slurry System—Yes[4]
Includes Timer—Yes[4]

Plan your fab