Keysight 4142 B, Signatone 1070, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
4142 BKeysight
1070Signatone
OEMKeysightSignatone
CategoryTest & ProbeTest & Probe
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyKeysight 4142 BSignatone 1070
Specifications
ArchitectureMainframe with 8 slots for plug-in measurement units[1]—
Integrated measurement functionsCurrent/voltage sources, nanovoltmeters, and picoammeters in one instrument[1]—
Source Monitor Unit (SMU) sensitivityForces voltage while measuring currents down to 20 fA; forces current while monitoring voltages down to 40 µV[1]—
HP 41420A High Power SMU2 slots; 40 µV to 200 V, 20 fA to 1 A (±200 V and ±1 A)[1]—
HP 41421B Medium Power SMU1 slot; 40 µV to 100 V, 20 fA to 100 mA (±100 V and ±100 mA)[1]—
HP 41422A High Current Unit (HCU)2 slots; pulse mode only; 100 µs pulsed measurements up to ±10 V and 10 A[1]—
HP 41423A High Voltage Unit (HVU)2 slots; DC or pulsed measurements to ±1000 V; low-leakage design measures currents down to 2 pA[1]—
HP 41425A Analog Feedback Unit (AFU)1 slot; used with two SMUs for analog voltage/current searches; finds target values in 12 ms[1]—
Maximum configuration coverage2000 V max using two HVUs; 20 A (pulsed) using two HCUs[1]—
Maximum output powerSum of all measurement units' instantaneous output power cannot exceed 32 W[1]—
Maximum common-to-ground voltage±42 V[1]—
Ground Unit (GNDU)High-current SMU set to 0 V, used as measurement ground; Kelvin connection; maximum offset voltage ±500 µV; current range ±1.6 A[1]—
Program memoryApprox. 2000 program steps, groupable into 99 subroutines[1]—
Data memoryMaximum 4095 data values (binary) or 1023 data values (ASCII)[1]—
Measurement modesPlug-in units operate individually or in synchronized modes to perform ten different types of measurements[1]—
InterfacesHP-IB; external trigger input (TTL, negative logic, minimum pulse width 100 µs); external trigger output (TTL, negative logic)[1]—
Self-test and calibrationSelf-test at power-up; offset errors in each measurement unit auto-calibrated every 30 minutes[1]—
Operating temperature5 °C to 40 °C[1]—
Operating humidity5% to 80% RH[1]—
Storage temperature and humidity-40 °C to 65 °C; <90% RH at 65 °C[1]—
Power requirements100/120/220 V ±10%; 240 V -10%/+5%; maximum 750 VA (48-66 Hz)[1]—
Dimensions426 mm W × 235 mm H × 676 mm D[1]—
WeightMainframe approx. 23 kg; plug-in units 2-3 kg each[1]—
Typical measurement time (SMU)HP 41420A/HP 41421B SMU (20 V/100 mA range, spot measurement): force I or V in 3.5 ms; measure I or V in 4.0 ms[1]—
Make—Signatone[2]
Model—1070[2]